In November 2026 Biamp put out Tesira firmware 5.7.2, a maintenance release that repairs a communication fault on some Voltera D and D M amplifiers, a power limit on the Voltera D 4800.4 and several paging and control issues, and it updated its Discovery Tool to version 1.2.0. For Cork venues, schools and offices with Biamp Tesira firmware on their amplifiers, paging stations or processors, the question is which of those fixes touches their own building.
Product image: Biamp.
- Biamp's release notes date Tesira firmware 5.7.2 to November 2026 and label it a firmware release; it covers Tesira, TesiraFORTÉ and Voltera D and D M amplifiers.
- Voltera D and D M amplifiers that ran firmware earlier than 5.0 and were then updated to 5.7.1 failed to communicate, and 5.7.2 resolves that.
- The Voltera D 4800.4 was not allowing 3600 W per channel; Biamp lists this as resolved.
- Paging fixes cover Max Page Level set over TTP not persisting on NPX paging stations, and paging station filter settings that waited for Bypass to be toggled.
- Security changes include a fix for Tesira devices that were using an expired HTTPS certificate, and an OpenSSH update to 10.5p1 for an SSH related CVE.
Biamp Tesira firmware 5.7.2 beyond the meeting room
Tesira is not only a meeting room platform: this release also reaches Voltera amplifiers and NPX paging stations. Biamp's announcement leads on Voltera and Dante, and the full release notes add a set of fixes for paging stations, third party control over TTP and TesiraFORTÉ X housekeeping. Those are the parts we focus on here, because they decide whether a hotel ballroom, a school corridor or a gym floor behaves the way it was designed to.
Our earlier post on the 5.7.1 firmware explains the release this one follows. Our story on Biamp gym audio in Adelaide gives a feel for the installed sound side of the range.
Five Cork scenarios
1. A city centre hotel that jumped to 5.7.1. Suppose a hotel's function rooms run on Voltera D amplifiers that sat on an old firmware version for years, and someone brought them straight up to 5.7.1. According to Biamp, Voltera D and D M amplifiers on firmware earlier than 5.0 failed to communicate after that update. 5.7.2 is the fix, so this site should move to it promptly.
2. A venue that wants every watt from a D 4800.4. A sports hall or event space using a Voltera D 4800.4 to drive demanding loudspeaker loads may have found it would not allow 3600 W per channel. Biamp lists that as resolved in 5.7.2.
3. A secondary school in Ballincollig with NPX paging stations. Picture a school using Biamp NPX paging stations for announcements, with the maximum page level for a zone set from a control system over TTP. Before 5.7.2, Biamp says that setting would not persist. A second fix means filter settings on paging stations now take effect when a configuration is sent, rather than only after Bypass was toggled.
4. An office in Mahon run by a third party control system. Where a control processor logs in to an older TesiraFORTÉ over TTP, Biamp records a 16 second login delay on TesiraFORTÉ Rev A units. Tesira 5.7.2 resolves it.
5. A Little Island business still on 4.x firmware. A site that has not touched its Tesira hardware for some years cannot jump straight to 5.7.2. Biamp's update path guidance says a move from 4.x to 5.7 or newer has to pass through a 5.x version older than 5.7, and it suggests 5.6.1 for that step.
Housekeeping fixes for TesiraFORTÉ X and Biamp Workplace
A handful of the resolved issues affect TesiraFORTÉ X processors and Biamp Workplace rather than audio itself:
- A factory reset on a TesiraFORTÉ X did not clear its configuration or its Biamp Workplace association.
- A Biamp Launch enabled TesiraFORTÉ X reported erroneous log messages about the DSP Task consuming more cycles.
- Biamp Workplace Command displayed the channels of multi channel level and metering blocks out of order.
- A rare Failed to Send Config could appear after changing the Media Clock master on a system.
Discovery Tool 1.2.0 sits alongside these. It finds the IP addresses of Devio SCX and TesiraFORTÉ X processors configured with Biamp Launch, and the new version again sees devices on firmware 5.7.0 and later. Biamp recommends the update.
One known issue remains open in 5.7.2: on TesiraFORTÉ X and TesiraCONNECT, the Enable IGMP Querier network setting is disabled whatever Tesira Software shows. Biamp notes that joining an IGMP multicast group still functions normally.
Updating amplifiers and paging without surprises
Biamp's normal update procedure has a few points that matter especially in buildings where sound is used all day. The firmware file for a Tesira or Voltera device is a .tfa or .tfa2 file applied from Device Maintenance in Tesira Software. NPX paging stations take a separate .qfa file. Every bit of audio stops during the update, typically for 5 to 15 minutes, and expanders configured in the system then take their turn, which Biamp says can take up to 15 minutes. If TesiraCONNECT TC-5 or TC-5D units are in the system, they update first.
Biamp also asks for the latest Tesira Software and Biamp Canvas before the firmware is applied, a saved copy of the running configuration, and a local network connection rather than WiFi or a remote internet link. For a hotel or school in Cork, that points to a planned visit outside trading or teaching hours, followed by a walk round every zone to confirm paging and background music.
1Install designs, supplies and installs meeting rooms, Teams Rooms and audio systems for buyers across Cork. Find out about our Teams Room installation in Cork, our audio conferencing work and our education AV, read our project process, or try the commercial quote builder.
Questions we are often asked
Which Biamp products does Tesira firmware 5.7.2 cover?
Tesira, TesiraFORTÉ and Voltera D and D M amplifiers, according to Biamp's November 2026 announcement.
Why did my Voltera amplifier stop communicating after the 5.7.1 update?
Biamp says this happened to Voltera D and D M amplifiers that were on firmware earlier than 5.0 before the 5.7.1 update. Tesira 5.7.2 resolves it.
Can a Voltera D 4800.4 deliver 3600 W per channel?
Yes, once on 5.7.2. Biamp lists a resolved issue where the Voltera D 4800.4 was not allowing 3600 W per channel.
Does Tesira 5.7.2 fix NPX paging station settings?
Yes. It resolves Max Page Level set over TTP not persisting on NPX paging stations, and filter settings not taking effect until Bypass was toggled.
Is Tesira firmware 5.7.2 a security update?
Partly. Biamp's notes include a fix for Tesira devices using an expired HTTPS certificate and an OpenSSH update to 10.5p1 to resolve an SSH related CVE.
Book a consultation or call our Cork office on 021 202 8107.
- Log in to post comments